Secrets For Passing IBM C5050-408 Exam: Latest Exam Questions 2017

If you want to place yourself in the best positions into the best IT companies, then you need to certify yourself with the most popular Worklight Foundation V6.2 C5050-408 certification exam. BrainDumps2017′ Exam Questions for IBM Mobile Application Development C5050-408 exam is prepared by the team of subject matter experts, professionals who have been grooming students for years. We provide you latest C5050-408 exam questions that are easy to learn and understandable for everyone. The C5050-408 Exam Questions is available in two easy formats, PDF files that you can carry anywhere easily to read.

C5050-408 exam questions, C5050-408 PDF dumps; C5050-408 exam dumps:: https://www.dumpsschool.com/C5050-408-exam-dumps.html (74 Q&A) (New Questions Are 100% Available! Also Free Practice Test Software!)

Latest and Most Accurate IBM C5050-408 Dumps Exam Questions and Answers:

Version: 8.0
Question: 21

An application developer wants to retrieve the client-side logs of an Android application that
is malfunctioning in the production environment.
When is the captured log data sent to the server?

A. After successful client init sequence.
B. When the application crashes.
C. When the application invokes the api console.log
D. When the application invokes the api Logger.setContext (Context)

Answer : A

Explanation: All captured log data, if any, is sent to the MobileFirst Server during each successful client network init sequence and invokeProcedure response, with a 60 second minimum interval between sends. References: https://www.ibm.com/support/knowledgecenter/SSHS8R_7.0.0/com.ibm.worklight.dev.doc/ devref/c_clientside_log_capture.html

Question: 22

The application developer wants to use raw data reports to obtain usage information about
the applications and adapters.
To enable raw data reports feature, the application developer needs to:

A. set reports.exportRawData property to true and configure the wl.reports.db properties to the databasesettings in the worklight.properties file.
B. set reports.exportRawData property to true and configure the wl.reports.db properties to the databasesettings in the application-descriptor.xml file.
C. stop Worklight Server, set reports.exportRawData property to true and configure the wl.reports.dbproperties to the database settings in the worklight.properties file, then restart Worklight Server.
D. stop Worklight Server, set reports.exportRawData property to true and configure the wl.reports.dbproperties to the database settings in the application-descriptor.xml file, then restart Worklight Server.

Answer : C

Explanation: Raw data reports provide you with analytics information about your applications and adapter usage, such as activity type, device information, and application version. Use the following steps to enable the raw data reports feature: Procedure ✑ Ensure that the IBM Worklight Server application server is not running. ✑ Create a separate database or a new schema for reports. ✑ When you work in a development environment, complete the following steps. 3a. Edit the worklight.properties file. Uncomment the reports.exportRawData property and set its value to true. 3b. Modify the wl.reports.db properties to contain your database settings as shown in the following example. ################################################# # Raw reports ################################################# reports.exportRawData=true # jndi name; empty value means Apache DBCP data source #wl.reports.db.jndi.name=${wl.db.jndi.name} # Default values for DBCP connection pool #wl.reports.db.initialSize=${wl.db.initialSize} #wl.reports.db.maxActive=${wl.db.maxActive} #wl.reports.db.maxIdle=${wl.db.maxIdle} #wl.reports.db.testOnBorrow=${wl.db.testOnBorrow} wl.reports.db.url=jdbc:mysql://localhost:3306/wlreport wl.reports.db.username=worklight wl.reports.db.password=worklight Ensure that the wl.reports.db.url property contains the URL of the database you are planning to use for raw data. 4 When you work in a production environment, connect to the reports database by using JNDI environment entries in addition to editing the worklight.properties file, as described in the previous step. 5. Restart your application server. References: https://www.ibm.com/support/knowledgecenter/SSZH4A_6.1.0/com.ibm.worklight.monitor.d oc/ admin/t_raw_data_reports.html

Question: 23

New Updated C5050-408 Exam Questions C5050-408 PDF dumps C5050-408 practice exam dumps: https://www.dumpsschool.com/C5050-408-exam-dumps.html

An application developer is concerned about how many requests may hit the adapter being created. The developer wants to ensure that the adapter can handle enough requests, but yet not allow requests to overwhelm the system.
What can the application developer do to limit the number of requests that an adapter will handle?

A. In the web server configuration, specify number of requests for MaxClients.
B. In the application server configuration, specify the number concurrent requests for the servlet engine.
C. In the loadContraints element of the adapter XML file, specify the number of requests formaxConcurrentConnectionsPerNode.
D. In the connectionPolicy element of the adapter XML file, specify the number of requests formaxConcurrentConnectionsPerNode.

Answer: D

Explanation:
Tuning Back-end Connections
maxConcurrentConnectionsPerNode – The maximum number of concurrent requests that can be performed on the back-end application from the Worklight server node. The worklight server will create a thread pool with maxConcurrentConnectionsPerNode size for that purpose. This maxConcurrentConnectionsPerNode parameter is set in the adapter.xml in the connectivity entry.
References: https://www.ibm.com/developerworks/community/blogs/worklight/entry/tuning_worklight_server?lang=en

Question: 24

An application developer is attempting to update specific portions of a hybrid application by utilizing the direct update feature.
Which components can the application developer update using the direct update feature without having to rebuild and deploy a new binary of the application?

A. HTML, CSS, JavaScript
B. HTML, CSS, JavaScript, Java
C. HTML, CSS, JavaScript, Objective C
D. HTML, CSS, JavaScript, Version number

Answer: A

Explanation:
When you want to deliver a Worklight hybrid application that consists mainly of HTML5 with CSS and JavaScript, and you must change the hybrid part of the application to provide new features or to fix a defect, you do not have to ask the application users to update it on their devices. You can use the Worklight direct update mechanism to deploy new HTML with CSS and JavaScript for your application without changing the application version on the mobile device.
Incorrect:
Not D: Delivering a new version of native code
The main reason that you would want to deliver a new version of an application is probably because your application uses native code and you want to provide new features or deliver fixes that require changes in the native code. You might also need to provide a new native version of the application, even if your Worklight application is completely written by using web technologies, to accommodate new mobile operating systems supported only in later versions of IBM Worklight. You cannot use the direct update mechanism in either of these cases. You must build and deploy a new version of the application.
Reference: http://www.ibm.com/support/knowledgecenter/SSZH4A_6.2.0/com.ibm.worklight.dev.doc/devenv/ c_update_apps_wl_ac.html

Question: 25

The application developer needs to test the Worklight application on a remote server. In Worklight Studio, the application developer configures the remote server by right clicking on the {app_name} folder and selecting Run As > Build Settings and Deploy Target.
Which step does the application developer need to perform to ensure the server configuration changes are reflected in the application?

A. Run As > Run on Server
B. Run As > Build and Deploy
C. Run As > Apply Build Settings
D. Run As > Build All Environments

Answer: D

Explanation:
The Build Settings and Deploy Target dialog is used only to specify configurations and settings; clicking OK does not trigger a build. Any time that you make a modification with this dialog, you must rebuild your application and environments for your changes to take effect, by using the Run As > Build All Environments menu command.
References: https://www.ibm.com/support/knowledgecenter/SSZH4A_6.1.0/com.ibm.worklight.dev.doc/dev/ c_building_and_deploying_build_settings_deploy_target.html

Question: 26

Which one of the following correctly describes the content of the corresponding Worklight Application folder?

A. services folder – Contains client side services.
B. server folder – Contains libraries to be placed in external service servers.
C. bin folder – Contains project artifacts that are deployed to the Worklight Server.
D. externalServerLibraries folder – Contains references for application development and deployment.

Answer: C

Explanation:
The bin folder contains project artifacts that are deployed to MobileFirst Server.
Incorrect:
Not D: externalServerLibraries: Contains the libraries to be placed in external service servers and used for access token validation (by the service).
References:
https://developer.ibm.com/mobilefirstplatform/documentation/getting-started-6-3/hello-world/creating-your-firsthybrid-application/

         

Facebook Comments